Dissolved oxygen meter
I have found results from10000+products and5000+suppliers aboutDissolved oxygen meter
Nobotech Smart Handheld Dissolved Oxygen Meter for Efficient Wastewater Analysis
Handheld Portable Dissolved Oxygen Meter DO Meter
Protection Grade IP66 Dissolved Oxygen Tester Do Meter for Aquarium
Biobase China pH Meters Benchtop Dissolved Oxygen Meter pH Meter for Labs
Low Cost Dissolved Oxygen Meter Do Sensor Water Measuring Device
Biobase China Portable Dissolved Oxygen Meter pH-820 with Salinity and Barometric Pressure Compensation for Lab
Portable Dissolved Oxygen Meter Optical Dissolved Oxygen Meter
Portable Multiparameter pH ORP Conductivity TDS Salinity Dissolved Oxygen Meter Chloride Water Analyzer
Portable pH and Dissolved Oxygen Meter (Color Screen) Multi-Parameter Tester
Portable Dissolved Oxygen Meter for on-Site Aquaculture Testing
Hach Ldo Dissolved Oxygen Meter and Probe System for Dissolved Oxygen Measurement
Advanced Benchtop Dissolved Oxygen Meter for Accurate Measurements
High-Quality Affordable Online Dissolved Oxygen Meter for Water Testing
Dissolved Oxygen Meter Maintenance free no need replace film and electrolyte MDS-410DO
Laboao LCD100t Desktop Touch Screen Conductivity Dissolved Oxygen Meter
Online Dissolved Oxygen Meter Fluorescence Dissolved Oxygen Meter
Benchtop Dissolved Oxygen Meter with LCD Display Screen
Industrial Process 0.01mg/L Resolution Dissolved Oxygen Meter for Environmental Water Testing
Gwq-Do280 Digital Aquaculture Analyzer Online Dissolved Oxygen Meter
Online Do Meter Dissolved Oxygen Analyzer for Wastewater Treatment Monitoring
High Precision Benchtop Dissolved Oxygen Meter for Laboratory Water Quality Testing
Conductivity Meter Soil Dissolved Oxygen Tester Portable pH Meter Digital Tester
Measure Water Aquaculture Optical Online Dissolved Oxygen Meter
Portable pH Mv Px Conductivity Ec TDS Salinity Dissolved Oxygen Ion Temperature Water Meter
Sourcing guidance for Dissolved Oxygen Meter
How to choose the right sensor technology for a Dissolved Oxygen (DO) Meter?
Buyers must choose between Optical (Luminescence) and Electrochemical (Polarographic/Galvanic) sensors. Optical sensors are highly recommended for long-term stability and low maintenance as they do not require membrane replacement or electrolyte refills and are not affected by H2S interference. Electrochemical sensors are more cost-effective for occasional spot-checking but require regular calibration and a constant flow of water across the membrane to provide accurate readings.
What are the key technical specifications to verify for industrial or laboratory use?
Ensure the device features Automatic Temperature Compensation (ATC), as oxygen solubility varies significantly with temperature. For high-accuracy requirements, look for Salinity and Barometric Pressure Compensation. The measurement range should ideally cover 0 to 20 mg/L (or 0-200% saturation) with an accuracy of ±1% or ±0.1 mg/L. For field use, an IP67 waterproof rating is essential to prevent damage from accidental submersion.
Which compliance standards and certifications are necessary for international trade?
Suppliers should provide CE certification for the European market and FCC for the US. For environmental monitoring or laboratory applications, check for ISO 9001 manufacturing standards and compliance with EPA-approved methods (like ASTM D888-12). If the meter is used in hazardous environments (e.g., oil & gas), ATEX or IECEx explosion-proof certification is mandatory.
What are the typical usage scenarios and how do they affect product selection?
Aquaculture and Fish Farming require portable, rugged meters with long battery life for daily pond checks. Wastewater Treatment Plants prioritize online, continuous monitoring systems with 4-20mA or RS485 Modbus outputs for integration into PLC systems. Laboratory Research demands high-precision benchtop models with data logging capabilities and USB/Bluetooth connectivity for easy data export.
Cross-Border Procurement Considerations for DO Meters
What are the common risks when sourcing high-precision instruments from overseas?
The primary risk is sensor degradation during transit or receiving a unit with a depleted electrolyte/expired membrane. Always request calibration certificates dated within 6 months. To mitigate risks, use Made-in-China.com's Secured Trading services to ensure the product meets technical specifications before final payment is released.
How should I negotiate with suppliers regarding consumables and maintenance?
DO meters are 'razor-and-blade' products. Negotiate for a bundle that includes extra sensor caps, membranes, and electrolyte solutions (for electrochemical models). Ask for a guaranteed supply of replacement parts for at least 5 years to avoid equipment obsolescence. For bulk orders, request a 2-3% spare parts allowance included in the initial price.
What are the shipping precautions for sensitive electronic sensors?
Sensors are sensitive to extreme temperatures and physical shock. Ensure the supplier uses anti-static packaging and shock-absorbent foam. If the meter includes a lithium battery, the supplier must provide a UN38.3 test report and MSDS to comply with international air freight regulations. For optical sensors, ensure they are stored in a moist environment (hydration bottle) during shipping to prevent the sensing element from drying out.
How can I verify the credibility of a Chinese manufacturer for scientific instruments?
Prioritize 'Audited Suppliers' on Made-in-China.com, as they have undergone third-party verification of their facilities. Request a video factory audit to see their calibration lab and QC testing area. A reliable manufacturer should be able to provide OEM/ODM customization and have a dedicated technical support team for troubleshooting via email or video call.





























