SourcingAI

Laminar air flow hood

I have found results from20000+products and5000+suppliers aboutLaminar air flow hood

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Type: Power
Type: Slit Type
Horizontal Flow Clean Bench
Type: Natural Ventilation
Vertical Flow Clean Bench
Type: Panel Filter
Structure: Open Frame
Certification: ISO9001:2000
All- packaged Type
Operation Voltage: High Voltage
Size: 1 Uint
Application Range: Power Plants
Shell Material: Stainless Steel
Shell Protection Grade: IP56
Customized: Customized
Portable: Portable
Noise: 40-60db
Application: Industrial
Control Mode: Touch
Usage: Dust Removal
Material: Stainless Steel
Function: Exhaust
Feature: Corrosion Resistance
Hood Type: Standard
Color: White
Condition: New
Capacity: Two Person
Engineers available to service machinery overseas
Clapboard: without Clapboard
Medium Material: Nonwoven Fabric
Filtration Grade: HEPA Filter
Standard: Standard
Fuel: Electric
Number of Nozzles: 24
Applicable Object: People Shower
Bilateral Air Shower
Certification: CE
Certification: RoHS
Certification: ISO9001
Certification: GS
Certification: ISO
Noise: ≤62DB
Noise: 60-70db
Noise: 20-40db
Application: Petrochemical Industry
Precision Electronic Industry
Application: Power Industry
Application: Mechanical Engineering
Application: Metallurgical Industry
Thermal Power Industry
Application: Transportation
Application: Building Industry
Application: Pharmaceutical,Food Industry
Application: Precision Industry
Application: Auto Industry
Application: Rubber Industry
Application: Financial Institutions
Control Mode: Button
Control Mode: Remote Control
Usage: Sterilization
Usage: Research Institute
Usage: Hospital
Usage: School
Usage: Company
Usage: Smoke Removal
Feature: Heat Resistant
Acid & Alkali Resistant
Feature: Fireproof
Feature: Explosion Proof
Feature: High Speed
Feature: Corrosion-Resistant
Feature: Heat-Resistant
Fast Shutter Door Air Shower Room
Automatic Door Air Shower
Intelligent Voice Air Shower
Hood Type: Floor Mounted
Color: Grey
Capacity: One Person
No overseas service provided
Standard: Nonstandard

Sourcing guidance for Laminar Air Flow Hood

What are the key technical specifications to consider when selecting a Laminar Air Flow Hood?

Buyers must prioritize HEPA or ULPA filtration efficiency, typically requiring 99.99% or higher for particles ≥ 0.3μm. Ensure the airflow velocity is maintained between 0.3 m/s to 0.5 m/s to guarantee a stable laminar stream. Additionally, check for low-noise centrifugal fans (ideally <60dB) and SUS304 stainless steel construction for the work surface to ensure chemical resistance and easy sterilization.

How do I determine whether to choose a Horizontal or Vertical airflow configuration?

Horizontal Flow is best for applications where the sample is sensitive to turbulence and no hazardous fumes are generated, as the air blows directly toward the operator. Vertical Flow is preferred for larger equipment placed on the work surface or when handling sterile compounding, as it minimizes the 'shadow effect' and provides better protection for the process by pushing air downward.

What international compliance standards should the equipment meet?

For global trade, the unit should comply with ISO 14644-1 Class 5 (formerly Federal Standard 209E Class 100) for air cleanliness. Ensure the supplier provides CE marking for electrical safety and EN 12469 or NSF/ANSI 49 if the unit is being used in biological applications. IQ/OQ/PQ validation documents are essential for pharmaceutical and medical device manufacturing.

What are the maintenance requirements for ensuring long-term performance?

The pre-filter should be replaced every 3-6 months to extend the life of the main filter. The HEPA filter typically requires replacement every 2-5 years depending on the environment. Regular DOP (Dispersed Oil Particulate) testing is recommended annually to check for filter leaks and ensure the integrity of the sterile environment.

Cross-Border Procurement & Risk Management for Laboratory Equipment

How can I mitigate the risk of damage during international shipping?

Laminar hoods contain sensitive filters and glass components. Insist on vacuum-sealed moisture-proof packaging and reinforced wooden crate packing (IPPC certified). Request the supplier to install 'TiltWatch' or 'ShockWatch' sensors on the exterior to monitor handling during transit. For high-value units, CIF (Cost, Insurance, and Freight) terms are recommended to ensure insurance coverage for maritime risks.

What strategies should be used when negotiating with suppliers on Made-in-China.com?

Focus on Total Cost of Ownership (TCO) rather than just the unit price. Negotiate for spare HEPA filters and UV lamps to be included in the initial shipment to save on future logistics costs. Ask for a video factory audit or a third-party inspection report (such as SGS or Intertek) before final payment to verify that the specific technical parameters meet your requirements.

How do I ensure transaction security and quality assurance?

Utilize Secured Trading Services on Made-in-China.com to protect your payment until the goods are shipped. Always request a Pre-Shipment Inspection (PSI) to verify the airflow velocity and particle count using calibrated meters. Ensure the contract specifies a warranty period of at least 12-24 months and guarantees the availability of replacement parts for 5 years.

What are the customs and regulatory considerations for importing to specific regions?

Verify the HS Code (typically 8414.60) to determine import duties in your country. Be aware that some regions require specific electrical certifications (like UL for the USA or CSA for Canada). Ensure all technical manuals and control panel interfaces are provided in English to avoid operational errors and compliance issues during local safety inspections.

Related queries