SourcingAI

Lithium battery charging cabinet

I have found results from30000+products and10000+suppliers aboutLithium battery charging cabinet

Commonly Used:
US$
—
Customization Available
Sample Available
Manufacturer First
Product Attributes:
Distribution Metering Box
Type: Li-ion Battery
Standard: GB
Tolerance: +/-0.10mm
Surface Treatment: Powder Coated
Machining Method: CNC Stamping
Material: Stainless Steel
Structure: Open Frame
Form: Partly-welded Type
Application Range: Power Plants
Shell Material: Stainless Steel
Cathode Material: LFP
Rechargeable: Yes
Size: Large
Connector Type: GB/T
Start Mode: Remote Control
One Pile with One Charge
Location: Public Use
Installation: Floor Type
Charge Method: Normal Charge
Weight: 35t
Nominal Voltage: 1331.2V
Layer: 2 Layers
Usage: Company
Color: Blue
Cycle Life: 8000 Cycles
Lab Type: Chemical laboratory
Customized: Customized
Condition: New
Resettlement: Hang-Mounted
Left Door Style
Portable Dry Powder Fire Extinguisher
Retirement Life: 5 Years
Standard: EN
China GB Code
Standard: JIS Code
Standard: TEMA
Standard: ASME
Tolerance: +/-0.01mm
Machining Method: Welding
Material: Steel
Material: Steel Type
Start Mode: APP Control
One Pile with Multiple Charges
Installation: Ming-Mounted
Charge Method: Quick Charge
Layer: 3 Layers
Usage: Hospital
Usage: Industrial
Usage: School
Usage: Research Institute

Sourcing guidance for Lithium Battery Charging Cabinet

What are the essential safety features to look for in a Lithium Battery Charging Cabinet?

Safety is the paramount concern for lithium storage. You must prioritize cabinets equipped with automatic fire suppression systems (such as aerosol or CO2 extinguishers) and smoke/heat detectors. Ensure the structure features double-walled steel construction with fire-resistant insulation (e.g., mineral wool) capable of withstanding internal temperatures for at least 60 to 90 minutes (EN 14470-1 standard). Additionally, pressure relief valves or 'explosion-proof' vents are critical to safely manage gas buildup during a thermal runaway event.

How should I evaluate the electrical and charging specifications for B2B procurement?

Verify that the cabinet supports Integrated Smart Charging Management, which includes overload protection, short-circuit protection, and individual socket monitoring. The internal wiring must handle the total current load; for high-capacity needs, look for industrial-grade power strips and RCD (Residual Current Device) protection. It is also vital to confirm thermal management systems, such as temperature-controlled ventilation fans, to prevent heat accumulation during the charging cycle.

What international compliance standards are mandatory for these products?

For global trade, the cabinet should ideally meet CE (European Conformity), RoHS, and specifically EN 14470-1 or EN 1363-1 for fire resistance. For the North American market, look for UL 60950 or UL 9540 (for energy storage systems) and compliance with NFPA 1 (Fire Code). Always request official test reports from third-party labs like TUV, SGS, or Intertek rather than relying solely on supplier claims.

Can the cabinet be customized for specific industrial usage scenarios?

Yes, professional suppliers on Made-in-China.com typically offer customization for socket types (EU, US, UK, AU), adjustable shelving to accommodate different battery sizes (e.g., e-bike batteries vs. power tool batteries), and IoT integration for remote monitoring via mobile apps or desktop dashboards. For outdoor use, ensure an IP54 or higher rating for water and dust resistance.

Cross-Border Sourcing & Risk Mitigation for Battery Cabinets

What are the primary risks when importing heavy fire-safety equipment?

The main risks include shipping damage affecting the structural integrity of fire seals and non-compliance with local fire department regulations, which could lead to insurance invalidation. To mitigate this, use heavy-duty wooden crate packaging and request a pre-shipment inspection (PSI) to verify that all fire-extinguishing components are active and the door-locking mechanisms function perfectly.

How should I negotiate with suppliers regarding quality assurance and logistics?

Negotiate for a warranty period of at least 2-3 years on the electronic components and a lifetime warranty on the fire-rated structure. Given the weight of these cabinets, FOB (Free On Board) is often preferred to maintain control over sea freight costs. Ask the supplier to provide HS Code 9403.10 (Metal furniture) or 8537.10 (Boards/Cabinets for electric control) to accurately calculate import duties before placing a bulk order.

What transaction security measures should be taken for high-value B2B orders?

Always utilize Secured Trading Services provided by Made-in-China.com to ensure your payment is held in escrow until delivery is confirmed. For large-scale enterprise orders, consider a 30% deposit and 70% balance payment against the Bill of Lading (B/L) after a successful third-party factory audit to verify the supplier's manufacturing capacity and QC processes.

Related queries